Your window is more than two sheets of glass. Here is what sits inside a sealed unit, how it fits into the frame, and the order in which the parts usually wear out.

A double glazing sealed unit is the part of your window most people simply call “the glass”. In fact, there is a surprising amount of engineering packed into that 24 or 28 mm.
Knowing how it’s built helps you understand why windows fail and what is worth repairing. It also makes it much easier to spot when someone is overselling, and to describe a problem clearly when you ring for a quote.
Below, we take a typical uPVC double glazed window apart, piece by piece. Then we rank the parts in the order they typically wear out.
Every double glazed window, whatever its age or style, comes down to three groups of parts:
Gaskets and glazing beads tie these together. Each part wears at a different rate, which is why one failing component rarely means the whole window has had it.
Think of a double glazing sealed unit as a thin, airtight box. Each layer has a specific job, and each one can fail in its own way.
Most domestic units use two panes of 4 mm glass. However, doors and low-level panes use toughened or laminated glass for safety. In modern units, one inner face carries an invisible low-emissivity (low-E) coating that reflects heat back into the room.
The spacer holds the panes apart, usually creating a gap of around 16–20 mm. Older units generally use shiny aluminium spacers. By contrast, modern units often use “warm edge” spacers made from plastic composites or thin stainless steel, which reduce cold spots and condensation around the edge.
Inside the hollow spacer sits a desiccant, a drying material that soaks up any moisture trapped during manufacture. Tiny holes along the spacer also let it work on the air in the cavity. Once the desiccant is saturated, misting appears between the panes.
The primary seal is a thin strip of butyl (polyisobutylene) between the spacer and each pane. It is the main barrier against water vapour, so it has to stay intact. Around the outside edge sits a secondary seal, usually polysulphide, polyurethane or silicone, which holds the whole unit together structurally.
Most modern units are filled with argon, a heavy, inert gas that slows heat transfer better than air. Some high-performance triple glazing uses krypton instead. You can’t see or test the gas fill at home, but you lose it once the seal fails.
| Component | What it does | Typical material |
|---|---|---|
| Glass panes | Let in light, keep weather out | 4 mm float, toughened or laminated glass |
| Low-E coating | Reflects heat back into the room | Microscopic metal oxide layer |
| Spacer bar | Holds the panes apart | Aluminium or warm-edge composite |
| Desiccant | Absorbs moisture in the cavity | Molecular sieve granules |
| Primary seal | Blocks water vapour | Butyl (polyisobutylene) |
| Secondary seal | Holds the unit together | Polysulphide, polyurethane or silicone |
| Gas fill | Reduces heat loss | Argon (krypton in some triple glazing) |
Sealed units sold in the UK are made to the European standard BS EN 1279. Meanwhile, the energy rules for replacement windows sit in Approved Document L of the Building Regulations.

The way a unit is fitted matters almost as much as the way it is made. Get it wrong and even a top-quality double glazing sealed unit can fail within a few years.
The unit doesn’t sit directly on the frame. Instead, it rests on small plastic packers that lift it clear of the bottom of the rebate. That gap lets any water that gets in run away through the drainage slots.
The packers also stop a heavy opening sash from dropping. Glaziers place them at specific points, often called toe and heel packing, so the weight of the glass helps keep the sash square.
Next come the glazing beads, which clip in around the edge to hold the unit in place. On most modern windows they sit on the inside, which is better for security. However, some older windows have them on the outside.
Gaskets, meanwhile, press against the glass on both sides to keep rain and draughts out. They also stop the edge seals sitting in direct sunlight, which helps the unit last longer.
A uPVC frame is made from hollow, multi-chambered profiles, welded at the corners. Larger frames carry steel reinforcement inside, which keeps them straight and gives screws something solid to grip.
The hardware, though, is where most day-to-day wear happens. On a typical casement window, you’ll find:
Doors follow the same idea on a bigger scale. They use heavy-duty hinges, a multipoint lock driven by a central gearbox, and a euro cylinder for the key.
We replace failed glass units, seals, hinges and mechanisms only, so you avoid the cost of a new window. Call 07951 152986 for a free survey and a fixed-price written quote.
Every window is different, and use, exposure and fitting quality all matter. Still, the same pattern shows up again and again.
In general, the small moving parts go first because they work hardest. The double glazing sealed unit comes later, and the frame usually outlasts everything.
| Part | Typical lifespan | First signs of trouble | Usual fix |
|---|---|---|---|
| Handles and small fittings | Around 5–15 years | Loose, floppy or stiff handle | New handle, often in minutes |
| Gaskets and weather seals | Around 10–15 years | Draughts, whistling, gaps at corners | Replace the gaskets |
| Friction stays (hinges) | Around 10–20 years | Sash drops, rubs or won’t close tight | Replace the stays |
| Door gearbox and multipoint lock | Around 10–15 years on busy doors | Stiff handle, key hard to turn | Replace the gearbox or lock |
| Double glazing sealed unit | Around 15–25 years | Misting or fogging between panes | Replace the unit only |
| uPVC frame | Around 25–35 years or more | Cracks, failed welds, warping | Replace the window |
Treat these as a rough guide, not a promise. Above all, remember that a failed part near the top of this table rarely justifies a new window.
Some double glazing sealed units last decades, while others mist up within a few years. The usual culprits are:
Once you know which part has failed, the decision becomes straightforward. Fix the failed component, and leave the healthy ones alone.
First, the engineer measures the width, height and thickness of the old unit and notes the glass type. Your new unit is then made to order, which typically takes a week or two. Then, on the day, fitting usually takes under an hour per window.
The engineer removes the beads, lifts out the old unit and checks the packers and drainage. Next, they fit the new unit, re-pack it and clip the beads back in. The frame stays exactly where it is, so there’s no mess around the brickwork.
Your window carries more information than you might think. Look along the spacer bar inside the unit, and you’ll often find printed text. It may include the manufacturer, the standard (BS EN 1279) and a production date.
That date is worth noting, because many sealed units carry a manufacturer’s guarantee. Knowing the age helps if one fails early.
Safety glass also carries its own small etched mark in a corner. Toughened glass references BS EN 12150, and laminated glass references BS EN 14449. The Glass and Glazing Federation publishes consumer guidance if you want to dig deeper.
Drill-and-vent demisting services exist, but they can’t restore the original seal or the gas fill. Replacing the unit is the reliable, long-term fix, and the frame stays in place.
Typically around 15–25 years, depending on quality, fitting and exposure. Units on sunny, exposed elevations and in frames with blocked drainage tend to fail sooner.
No. The sealed unit is only the glass part, whereas the window also includes the frame, gaskets, hinges, handles and locks, and each can be repaired separately.
Usually, yes, as long as the new unit matches the thickness the frame takes. That way you can upgrade to modern coated glass without replacing the window.
We work right across the town, including sealed unit replacement in Brighton Hill and window repairs in Old Basing. For the full list, see our areas we cover page.
Once you know how a sealed unit is built, the next question is whether to upgrade it. Our Surrey team explains how to upgrade double glazing units while keeping your existing frames.
A double glazed window is a set of parts, not a single object. The double glazing sealed unit, gaskets, hinges and locks all wear at different speeds, and each one can be replaced on its own.
So when something goes wrong, identify the failed part first. Have a look at our double glazing repair services, or send us a photo and a few details and we’ll tell you what we think has failed.
You deal directly with a Basingstoke repair specialist, not a call centre. Our DBS-checked, insured engineers give clear, fixed-price quotes before any work begins. Call 07951 152986 today.